Providing Solutions for your Bottom Line and the Environment

 

Home  |  Catalog  |  Test Data  | Shopping Cart  |  FAQ  |  Savings Calculator  |  Community Partnerships  |  Contact Us

 

MSDS - 16 oz.

Bottles

 

 

DurAlt® Fuel Conditioner

(757) 565-6363

save@fuel-n-ovations.com

 

 

Manufactured for Polar Molecular Corporation                                                                                                                                               1-31-06

GPMC-101 DurAlt® Fuel Conditioner (FC)                                                                                                                                             Page 1 of 3

 

 

 

MATERIAL SAFETY DATA SHEET

 

 

 

SECTION I 

 

 

PRODUCT NAME OR NUMBER (as it appears on label)

GPMC-101 DurAlt® Fuel Conditioner (FC)

 

 

MANUFACTURER’S FOR

Polar Molecular Corporation

   

EMERGENCY TELEPHONE NO.

(303) 221-1908 M -F 8:30am - 5:00pm Mountain

CHEMTREC: (800) 424-9300 ALL OTHER TIMES

 

ADDRESS (Number, Street, City, State and Zip Code)

4600 S. Ulster Street, Suite 940

Denver  CO  80237

 
 

MANUFACTURER’S D-U-N-S NO.

00-532-0551

HAZARDOUS MATERIALS DESCRIPTION, PROPER SHIPPING NAME, HAZARD CLASS ID NO.

Combustible Liquid   

 

 

ADDITIONAL HAZARD CLASSES (as applicable)

 

Combustible Liquid  

CHEMICAL FAMILY

Solvent Blend

 

FORMULA

Patented 

 

 

 

 

 

SECTION II - INGREDIENTS/HAZARDOUS INGREDIENTS

 

 

 

 

 

 

CAS

 REGISTRY

NO.

 

%V        

 

 

%W         

 

 

CHEMICAL NAMES    

 

 

EXPOSURE LIMITS IN AIR

    (units in ppm)

                    OSHA

ACGIH     TWA STEL   VENDOR

 

Listed as a

Carcinogen in

NTP IARC or

 OSHA 1910

  64742-98-9

  25-35

 

Oxygenated Hydrocarbon 

N/AV        N/AV   N/AV       N/AV 

No 

  111-76-2

 10-20

15.6* 

Ethylene Glycol Monobutyl Ether 

Skin 25     25       N/E        25/50

Air    50    100      N/E        100

No 

64742-94-5 

15-25

15-25 

Hydrocarbon Petroleum Distillate 

25            N/E     N/E         100 

No 

 111-87-5

15-25

 

Octanol 

Skin 25      25     N/E         25/50 

No 

64742-46-7 

  10-20

 

Petroleum Oil 

N/E    50mg/M3   N/E    50mg/M3

              (Mist)                  (Mist) 

 

No

  Proprietary

   <1

 0.7*

 

Resin in Aromatic Hydro-

Carbons, Naphthalene 

 

N/E           N/E     N/E         N/E

 

No

 

*Toxic chemical or chemicals subject to the reporting requirements of Section 313 of Title III and of 40 CFR 372.

 

 

 

 

Manufactured for Polar Molecular Corporation                                                                                                                                              1-31-06

GPMC-101 DurAlt® Fuel Conditioner (FC)                                                                                                                                             Page 2 of 3

 

 

SECTION III - PHYSICAL DATA

 

 

BOILING RANGE    330-400 ° F                            °C

 SPECIFIC GRAVITY (H2O=1)     0.89

VAPOR PRESSURE    N/A

@ 68°F               °C         XX mm Hg          psi

VOLATILE BY VOLUME               100%

PERCENT SOLID BY WEIGHT       0%

VAPOR DENSITY (Air=1)   Not Available

EVAPORATION RATE   Slower than Ether

 

SOLUBILITY IN WATER         0%  

 

pH     None

  APPEARANCE AND ODOR    Amber liquid, aromatic odor

IS MATERIAL:      LIQUID--XX                  SOLID                         GAS                       PASTE                 POWDER 

 

 

 

SECTION IV - FIRE AND EXPLOSION HAZARD DATA 

 

 

                                                                                       Method Used          

            FLASH POINT       143° F                °C                   T.C.C.         

                                                        LEL             UEL                          FLAMMABLE LIMITS                          N/AV          N/AV

EXTINGUISHING MEDIA:  CO2,  dry chemical, foam or other National  Fire Protection Association (NFPA) approved method for treating a Class B fire.   

SPECIAL FIRE FIGHTING PROCEDURES:  Summon professional firefighters.  Use full protective equipment including self-contained breathing apparatus.  Water spray may be ineffective.   If water is used, fog nozzles are preferable.  If exposed to fire or extreme heat, water should be used to cool closed containers and prevent pressure build-up or possible auto-ignition. 

UNUSUAL FIRE AND EXPLOSION HAZARDS: Keep containers tightly closed.  Isolate from heat and flame.  Due to pressure build-up, closed containers exposed to extreme heat may explode.  Never use a welding or cutting torch on or near container (even empty) as product or its residue may ignite.  During emergency conditions, overexposure to decomposition products may cause a health hazard.  Symptoms may not be immediately apparent.  Obtain medical attention. 

 

 

 

SECTION V - HEALTH HAZARD DATA 

 

THRESHOLD LIMIT VALUE: See Section II

PERMISSIBLE EXPOSURE LIMIT: See Section II

OTHER LIMIT   See Section II

                                                             

EFFECTS OF OVEREXPOSURE: Acute - Breathing - Irritation of the respiratory tract; headache, nausea, dizziness, weakness and fatigue.  Extreme exposure can result in unconsciousness and even respiratory arrest.  Eye Contact - Severe irritant.  May cause eye burns.  Skin Contact - Prolonged and repeated liquid contact can cause defatting and drying of the skin, which may result in skin irritation and dermatitis.  May cause skin burns.  May cause allergic skin reaction.  May be absorbed by the skin.  Swallowing - Vomiting may result.  Pulmonary aspiration hazard if vomiting occurs. 

CHRONIC: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage. 

PRIMARY ROUTES OF ENTRY:   Inhalation, skin contact, eye contact, ingestion.

EMERGENCY AND FIRST AID PROCEDURES: If Breathed - If you experience difficulty in breathing, leave the area to obtain fresh air.  If continued difficulty is experienced, summon medical assistance immediately.  If breathing ceases, restore using approved CPR techniques and summon medical assistance immediately.  If In Eyes - Flush immediately with large amounts of water for at least 15 minutes.  Get medical assistance.  If On Skin - Wash affected areas with soap and water.  Remove soiled clothing.  Get medical assistance if irritation persists.  Wash clothing before reuse.  If Swallowed - DO NOT INDUCE VOMITING.  Consult a physician immediately.  Aspiration of vomitus can cause chemical pneumonitis which can be fatal. 

 

 

 

 

 

Manufactured for Polar Molecular Corporation                                                                                  1-31-06

GPMC-101 DurAlt® Fuel Conditioner (FC)                                                                                   Page 3 of 3

 

 

 

SECTION VI - REACTIVITY DATA

 

                  STABILITY: 

UNSTABLE                  STABLE        XX         

CONDITIONS TO AVOID: Heat, sparks, flame. 

INCOMPATIBILITY (materials to avoid) Strong oxidizing agents.  

HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition may yield carbon monoxide and carbon dioxide. 

    HAZARDOUS         POLYMERIZATION   

                                    

MAY OCCUR                 WILL NOT OCCUR       XX   

                                                                                                                    

CONDITIONS TO AVOID: Elevated temperatures, contact with oxidizing agents, sparks, open flame, ignition sources.

 
 


SECTION VII - SPILL OR LEAK PROCEDURES

STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Remove all sources of ignition (flames, hot surfaces, and electrical, static or frictional sparks).  Do not smoke.  Prevent breathing vapors.  Ventilate area.  Before attempting clean-up, refer to hazard caution information in other sections of this material safety data form.  Dike and contain spilled material and remove with inert absorbent and non-sparking tools.  Store in closed container until properly disposed of. 

 

WASTE DISPOSAL METHOD: Dispose of in accordance with local, state and federal regulations.  Incinerate only in approved facility.  Do not incinerate closed containers. 

CERCLA (Superfund) REPORTABLE QUANTITY (in lbs.):    One pound or refer to Section 311 Clean Water Act. 

RCRA HAZARDOUS WASTE NO. (40 CFR 261.33)       Not Applicable 

VOLATILE ORGANIC COMPOUND (VOC):           (as packaged, minus water)   100% 

 XX          Theoretical      7.5        lb/gal                      XX            Analytical                 7.5         lb/gal 

 

 

SECTION VIII - SPECIAL PROTECTION INFORMATION

RESPIRATORY PROTECTION: When used in restricted ventilation areas, wear NIOSH/MSHA approved chemical/mechanical filters designed to remove a combination of particulates and vapor.  When used in confined areas, wear NIOSH/MSHA approved air supply respirators or hoods.  Follow respirator manufacturer’s directions for respirator use.  If respirators are used, a program should be established to assure compliance with OSHA Standard 29 CFR 1910.134. 

VENTILATION:   Use only with adequate ventilation.  Use either local exhaust or mechanical to meet TLV requirements.  Ventilation  must  be sufficient to limit employee exposure at, or below, applicable health and safety standards.  Heavy solvent vapors should be removed from lower levels of work area. 

PROTECTIVE GLOVES: Butyl rubber and F.E. P. teflon.  EYE PROTECTION: Solvent resistant safety eyewear with splash guards.  OTHER PROTECTIVE EQUIPMENT: Eye bath and safety shower.  Solvent impermeable clothing to prevent skin contact. 

 

 

SECTION IX - SPECIAL PRECAUTIONS

 

PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: Keep away from heat, sparks and flame.  Do not smoke.  Prevent  build-up of vapors by maintaining continuous flow of fresh air.  Do not store above 125°F or near fire or open flame.  Store large quantities in buildings to comply with OSHA 1910.106.  Keep container closed when not in use.  Do not transfer contents to bottles or other unlabeled containers.  Do not reuse empty containers.  Keep out of reach of children. 

 

 

The technical information stated herein is based upon research and experience of Polar Molecular Corporation and is believed to be reliable,   but such information does not constitute a warranty nor should be construed as permission or recommendation to use any invention covered   by a patent.  Since Polar Molecular Corporation has no control over the conditions under which its products are transported, stored, handled, and/or used, the purchaser and/or user must determine for themselves, via preliminary tests or otherwise, the suitability of the products for    their specific purposes.

 

Copyright 2006 Fuel-N-Ovations.  All Rights Reserved.