Manufactured for Polar Molecular Corporation                                                                                                                                             1-31-06

GPMC-121 DurAlt ® - Gasoline  (CFC)                                                                                                                                                  Page 1 of 3

 

                            

 

MATERIAL SAFETY DATA SHEET  

 

SECTION I 

PRODUCT NAME OR NUMBER (as it appears on label)

GPMC-121 DurAlt® - Gasoline (CFC) 

                            

MANUFACTURERS FOR

Polar Molecular Corporation 

EMERGENCY TELEPHONE NO.

(303) 221-1908 M -F 8:30am-5:00pm Mountain

CHEMTREC: (800) 424-9300 ALL OTHER TIMES

ADDRESS (Number, Street, City, State and Zip Code)

4600 S. Ulster Street, Suite 940

Denver  CO  80237 

MANUFACTURER'S D-U-N-S NO.

00-532-0551

HAZARDOUS MATERIALS DESCRIPTION, PROPER SHIPPING NAME, HAZARD CLASS ID NO.

Combustible Liquid 

ADDITIONAL HAZARD CLASSES (as applicable) 

Combustible Liquid

 CHEMICAL FAMILY

Solvent Blend

FORMULA

Patented

  

 

 

 

 

SECTION II - INGREDIENTS/ HAZARDOUS INGREDIENTS 

 

               

 

 CAS REGISTRY NO.  

                 

      %V   

                  

%W

 

CHEMICAL NAMES  

                     

EXPOSURE LIMITS IN AIR    

(units in ppm)          

          OSHA  ACGIH     TWA STEL   VENDOR                           

Listed as a

 Carcinogen in

 NTP IARC or

 OSHA 1910

64742-98-9

 

63-73

Oxygenated Hydrocarbon

N/AV        N/AV   N/AV       N/AV

No

111-76-2

 

17-27*

Ethylene Glycol Monobutyl

Ether

Skin 25     25       N/E        25/50

Air    50    100      N/E        100

No

     111-87-5 

15-25  

Octanol

Skin 25      25     N/E         25/50

No

Proprietary

 

<1 *

Resin in Aromatic

N/E           N/E     N/E         N/E

No

     

Hydrocarbons,

Naphthalene

   

 *Toxic chemical or chemicals subject to the reporting requirements of Section 313 of Title III and of 40 CFR 372

 


SECTION III - PHYSICAL DATA

 
 

     BOILING RANGE    313-650       XX °F                            °C

     SPECIFIC GRAVITY (H2O=1)      0.88

     VAPOR PRESSURE    N/A

     @ 68°F               °C         XX mm Hg          psi

     VOLATILE BY VOLUME               100%

     PERCENT SOLID BY WEIGHT        0%

     VAPOR DENSITY (Air=1)   N/A

     EVAPORATION RATE   Slower than Ether

     SOLUBILITY IN WATER         20%   

     pH     N/A

     APPEARANCE AND ODOR    Amber liquid, aromatic odor

     IS MATERIAL:      LIQUID--XX                  SOLID                         GAS                       PASTE                 POWDER

 

 
 

Manufactured for Polar Molecular Corporation                                                                                                                                             1-31-06

GPMC-121 DurAlt ® - Gasoline  (CFC)                                                                                                                                                  Page 2 of 3

 

 

 

 

 

SECTION IV - FIRE AND EXPLOSION HAZARD DATA
 
 

                                                                                        Method Used

     FLASH POINT        150 °F             °C                          T.C.C. 

                                                                  LEL             UEL   

     FLAMMABLE LIMITS                             N/A             N/A   

     EXTINGUISHING MEDIA:    CO2,   dry chemical, foam or other National Fire Protection Association (NFPA) approved method for treating a Class B fire. 

     SPECIAL FIRE FIGHTING PROCEDURES: Summon professional firefighters.  Use full protective equipment including self-contained breathing apparatus.  Water spray may be ineffective.  If water is used, fog nozzles are preferable.  If exposed to fire or extreme heat, water should be used to cool closed containers and prevent pressure build-up or possible auto-ignition. 

     UNUSUAL FIRE AND EXPLOSION HAZARDS: Keep containers tightly closed.  Isolate from heat and flame.  Due to pressure build-up, closed containers exposed to extreme heat may explode.  Never use a welding or cutting torch on or near container (even empty) as product or its residue may ignite.  During emergency conditions, overexposure to decomposition products may cause a health hazard.  Symptoms may not be immediately apparent.  Obtain medical attention. 

 
 

 

SECTION V - HEALTH HAZARD DATA
 
 

     THRESHOLD LIMIT VALUE: See Section II    PERMISSIBLE EXPOSURE LIMIT:     See Section II                                                  

     OTHER LIMIT: See Section  II                                                                                                                                                         

    EFFECTS OF OVEREXPOSURE: Acute - Breathing - Irritation of the respiratory tract; headache, nausea, dizziness, weakness and fatigue.  Extreme exposure can result in unconsciousness and even respiratory arrest.  Eye Contact - Severe irritant.  May cause eye burns.  Skin Contact - Prolonged and repeated liquid contact can cause defatting and drying of the skin, which may result in skin irritation and dermatitis.  May cause skin burns.  May cause allergic skin reaction.  May be absorbed by the skin.  Swallowing - Vomiting may result.  Pulmonary aspiration hazard if vomiting occurs.  CHRONIC: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage.

     PRIMARY ROUTES OF ENTRY:   Inhalation, skin contact, eye contact, ingestion.

EMERGENCY AND FIRST AID PROCEDURES: If Breathed - If you experience difficulty in breathing, leave the area to obtain fresh air.  If continued difficulty is experienced, summon medical assistance immediately.  If breathing ceases, restore using approved CPR techniques and summon medical assistance immediately.  If In Eyes - Flush immediately with large amounts of water for at least 15 minutes.  Get medical assistance.  If On Skin - Wash affected areas with soap and water.  Remove soiled clothing.  Get medical assistance if irritation persists.  Wash clothing before reuse.  If Swallowed - DO NOT INDUCE VOMITING.  Consult a physician immediately.  Aspiration of vomitus can cause chemical pneumonitis which can be fatal.  MEDICAL CONDITIONS PRONE TO AGGRAVATION BY EXPOSURE: None when used in accordance with Special Protection. Information (Section VIII).WARNING: Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal.

 

 

 
 

SECTION VI - REACTIVITY DATA 

 
 

     STABILITY:

 UNSTABLE                  STABLE        XX         

CONDITIONS TO AVOID: Heat, sparks, flame.

      INCOMPATIBILITY (materials to avoid) Strong oxidizing agents.

     HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition may yield carbon monoxide and carbon dioxide.

     HAZARDOUS POLYMERIZATION

     MAY OCCUR                 WILL NOT OCCUR       XX   

     CONDITIONS TO AVOID: Elevated temperatures, contact with

       oxidizing agents, sparks, open flame, ignition sources.

 

Manufactured for Polar Molecular Corporation                                                                                                                                             1-31-06

GPMC-121 DurAlt ® - Gasoline  (CFC)                                                                                                                                                  Page 3 of 3 

 

 

 

 

SECTION VII - SPILL OR LEAK PROCEDURES

 

     STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Remove all sources of ignition (flames, hot surfaces, and electrical, static or frictional sparks).  Do not smoke.  Prevent breathing vapors.  Ventilate area.  Before attempting clean-up, refer to hazard caution information in other sections of this material safety data form.  Dike and contain spilled material and remove with inert absorbent and non-sparking tools.  Store in closed container until properly disposed of.

     WASTE DISPOSAL METHOD: Dispose of in accordance with local, state and federal regulations.  Incinerate only in approved facility.  Do not incinerate closed containers.

     CERCLA (Superfund) REPORTABLE QUANTITY (in lbs.):    One pound or refer to Section 311 Clean Water Act.

     RCRA HAZARDOUS WASTE NO. (40 CFR 261.33)       N/A

     VOLATILE ORGANIC COMPOUND (VOC):   (as packaged, minus water)    100%

             XX          Theoretical      7.35        lb/gal                      XX              Analytical             7.255    lb/gal

 

  

SECTION VIII - SPECIAL PROTECTION INFORMATION

 

     RESPIRATORY PROTECTION: When used in restricted ventilation areas, wear NIOSH/MSHA approved chemical/mechanical filters designed to remove a combination of particulates and vapor.  When used in confined areas, wear NIOSH/MSHA approved air supply respirators or hoods.  Follow respirator manufacturer?s directions for respirator use.  If respirators are used, a program should be established to assure compliance with OSHA Standard 29 CFR 1910.134. 

     VENTILATION:   Use only with adequate ventilation.  Use either local exhaust or mechanical to meet TLV requirements.  Ventilation must be sufficient to limit employee exposure at, or below, applicable health and safety standards.  Heavy solvent vapors should be removed from lower levels of work area. 

     PROTECTIVE GLOVES: Butyl rubber and F.E. P. teflon.  EYE PROTECTION: Solvent resistant safety eyewear with splash guards.  OTHER PROTECTIVE EQUIPMENT: Eye bath and safety shower.  Solvent impermeable clothing to prevent skin contact. 

 

 

 

SECTION IX - SPECIAL PRECAUTIONS

 

     PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: Keep away from heat, sparks and flame.  Do not smoke.  Prevent build-up of vapors by maintaining continuous flow of fresh air.  Do not store above 125?F or near fire or open flame.  Store large quantities in buildings to comply with OSHA 1910.106.  Keep container closed when not in use.  Do not transfer contents to bottles or other unlabeled containers.  Do not reuse empty containers.  Keep out of reach of children.

  

The technical information stated herein is based upon research and experience of Polar Molecular Corporation and is believed to be reliable, but such information does not constitute a warranty nor should be construed as permission or recommendation to use any invention covered by a patent.  Since Polar Molecular Corporation has no control over the conditions under which its products are transported, stored, handled, and/or used, the purchaser and/or user must determine for themselves, via preliminary tests or otherwise, the suitability of the products for their specific purposes.

 